Asian Journal of Pharmaceutical Analysis

  • Year: 2012
  • Volume: 2
  • Issue: 3

Analytical Method Development and Method Validation for the Simultaneous Estimation of Metformin hydrochloride and Pioglitazone hydrochloride in Tablet Dosage Form by RP-HPLC

  • Author:
  • Jajow Swapna, Chandaka Madhu, Mallepelli Srivani, M. Sumalatha, Y. Nehalatha, Y. Anusha
  • Total Page Count: 5
  • DOI:
  • Page Number: 85 to 89

Sri Indu College of Pharmacy, Sheriguda, Hyderabad (A.P)-501 301, India

Abstract

A simple, sensitive and rapid reverse phase high performance liquid chromatographic method was developed for the estimation of Metformin HCl (MET) and Pioglitazone (PIO) in pure and in pharmaceutical dosage forms. A BDS Hypersil C18 column (250x4.6mm, 5μ) was used with a mobile phase containing a mixture of Acetonitrile and Potassium dihydrogen ortho phosphate buffer (pH-3) in the ratio of 50: 50. The flow rate was 1ml/min and effluents were monitored at 238nm and eluted at 2.81min (MET) and 4.57min (PIO). Calibration curve was plotted with a range from 40–240 μg/ml for MET and 12–72 μg/ml for PIO. The assay was validated for the parameters like accuracy, precision, specificity, robustness, ruggedness and system suitability parameters. The proposed method can be useful in the routine analysis for the determination on metformin and pioglitazone in pharmaceutical dosage forms.

Keywords

Metformin Hydrochloride, Pioglitazone Hydrochloride, Reverse phase HPLC, Pharmaceutical dosage forms, simultaneous estimation