Asian Journal of Research in Chemistry

  • Year: 2018
  • Volume: 11
  • Issue: 2

New High Performance Liquid Chromatographic Method for Determination of Vilazodone HCl in Pharmaceutical Dosage Form

1Department of Pharmacy, SRMSCET, Bareilly, Uttar Pradesh, India

2B. N. Institute of Pharmaceutical Sciences, Udaipur, RAJ, India

Abstract

A simple, precise, rapid and accurate reverse phase HPLC method developed for the estimation of Vilazodone in Tablet dosage form by using a C8 Chromasil column (250 × 4.6 mm, 5μm particle size), with mobile phase containing mixture of phosphate buffer and methanol in ratio of 30: 70, v/v with pH adusted to 5 with orthophosphoric acid was used. The flow rate was 1 ml/min and the effluents were monitored at 232 nm. The retention time was 6.008 min. The detector response was linear in the concentration of 4–20 mcg/ml. The respective linear regression equation being y = 66733x-4974. The limit of detection and limit of quantification was 0.418and 1.267mcg/ml respectively. The percentage assay of Vilazodone was 100.15%. The method was validated by determining its system suitability, precision, accuracy, and robustness parameters.. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate; this is useful for the routine determination of Vilazodone in bulk drug and in its pharmaceutical dosage form.

Keywords

Vilazodone, Calibration curve, RP-HPLC, Estimation, and Tablets