Establishment and Application of a TaqMan-MGB Multiplex Real-time Fluorescent Quantitative PCR Assay for Detecting Common Pathogens Causing Bovine Mastitis

  • Author:
  • Xiaoyue Wang1,2,*#, Xiaoli Zhang3,**#, Liyun Chang4, Zijia Zhang2, Yuechuan Sun1,2, Zhiyong Liu2, Lixue Dong2
  • Total Page Count: 8
  • Page Number: 1596 to 1603

1Tangshan Academy of Agricultural Sciences, Tangshan063000, China

2Tangshan Center for Animal Disease Control and Prevention, Tangshan063000, China

3Tangshan Animal Quarantine Station, Tangshan063000, China

4Tangshan Normal University, Tangshan063000, China

*Corresponding Author: Lixue Dong, Tangshan Center for Animal Disease Control and Prevention, Tangshan063000, China, Email: wangxiaoyue821@163.com

**Corresponding Author: Zhiyong Liu, Tangshan Center for Animal Disease Control and Prevention, Tangshan063000, China, Email: tslzy2005@163.com

#These authors contributed equally to this work.

Abstract

The aim of this study was to establish a TaqMan-MGB multiplex real-time fluorescent quantitative PCR assay for the simultaneous detection of four pathogens, enabling rapid and effective identification of the etiological agents of bovine mastitis.

Specific primers and TaqMan-MGB probes were designed targeting the conserved gene sequences of Staphylococcus aureus, Escherichia coli, Salmonella spp and Pseudomonas aeruginosa. After optimizing reaction conditions including primer/ probe concentrations and annealing temperature, a multiplex real-time PCR assay was established. Specificity, sensitivity and repeatability tests were conducted and the established method was applied to detect 192 clinical samples.

The amplification efficiencies of the 4-plex real-time PCR assay were all above 90%, with correlation coefficients R2 exceeding 0.99, indicating high amplification efficiency. The assay specifically amplified S. aureus, E. coli, Salmonella spp and P. aeruginosa, with no cross-reactivity with Bacillus cereus, Klebsiella spp, or Listeria spp, demonstrating strong specificity. The assay exhibited high sensitivity, with the minimum detection limits of 1.85×101 copise/μL for S. aureus, 2.02×101 copise/μL for E. coli, 1.93×101 copise/μL for Salmonella spp and 1.89×101 copise/μL for P. aeruginosa. Repeatability tests revealed intra-assay coefficients of variation (CV) less than 1.86% and inter-assay CV less than 2.68%, confirming good reproducibility. When applied to 192 clinical milk samples, the coincidence rate of the 4-plex assay with conventional single-plex PCR for detecting mixed infections with the four bacteria was 83.30% and the overall coincidence rate between the two methods was 95.70%. The established 4-plex real-time PCR assay provides a valuable tool for the detection of bovine mastitis pathogens, guiding clinical medication and facilitating molecular epidemiological studies.

Keywords

Bovine mastitis, Detection method, Multiplex real-time fluorescent quantitative PCR, TaqMan-MGB