International Journal of Advanced Research in Engineering and Applied Sciences
  • Year: 2015
  • Volume: 4
  • Issue: 4

Profit analysis of a two-unit centrifuge system considering the halt state on occurrence of minor/major fault

  • Author:
  • Shakeel Ahmad, Vinod Kumar
  • Total Page Count: 15
  • Page Number: 94 to 108

*Research Scholar, Department of Statistics, Shri Jagdish Prasad Jhabarmal Tibrewala University, Dist Jhunjhunu, Rajasthan, India

**Professor and Head, Department of Mathematics, Shri Baba Mast Nath Engineering College, Asthal Bohar, Rohtak, Haryana, India

Online published on 10 March, 2016.

Abstract

The present paper deals with a two identical unit cold standby centrifuge system considering major/minor fault. It is assumed that system leads to partial failed state on occurrence of a minor fault whereas on occurrence of a major fault it leads to complete failure. Some time the system is need to be brought at halt state for repair/replacement (off-line) and repairs/replacements of the system/components is done. In general on complete failure of the system, the repairman first inspect whether the fault is repairable or non repairable and accordingly carry out the repair or replacement of the components involved. Various measures of system effectiveness are obtained by using Markov processes and regenerative point technique. The analysis of the system is carried out on the basis of the graphical studies and conclusions are drawn regarding the reliability of the system.

Keywords

Centrifuge System, MTSF, Expected Uptime, Profit, Markov Process, Regenerative Point Technique