Parametric study on thermal shield cool-down: Effect of various flow conditions

  • Author:
  • Jotirmoy Das1,, Hitensinh Vaghela1, Ritendra Bhattacharya1, Pratik Patel1, Ketan Choukekar1, Vinit Shukla1, Nitin Shah1, Biswanath Sarkar1
  • Total Page Count: 6
  • Published Online: Jan 1, 2016
  • Page Number: 97 to 102

1ITER-India, Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar, Gujarat-382428 (India)

*Email: jotirmoy.das@iter-india.org

Abstract

Thermal performance criterion of the TACB (Test Auxiliary Cold Box) dictates the need for an effective thermal shield between the ambient temperature at 300 K and the cold mass at 4 K, in line with the maximum heat load limitation of the cryoplant at 4 K temperature level. This thermal shield, to be forced flow cooled and maintained at 80 K temperature level will screen direct thermal conduction and radiation heat loads from the ambient to the cold mass. The design objective is to attain cool-down of the shield within a desired time frame with least possible cryogen mass flow rate and pressure drop across the thermalization channel while adhering to the allowable heat load limit at 80 K temperature level. In the present paper, a transient thermal analysis is carried out by varying the process conditions, i.e. pressure and mass flow rate of the cooling fluid to compare time dependent thermal characteristics of the shield during cool-down and decide the optimum flow parameters from the available range.

Keywords

Thermal shield, Cool-down time, Transient thermal analysis, ANSYS®