Thermohydraulic analysis of hydroformed radiation shield plate

  • Author:
  • Jatin J Chopra1,, Samiran Mukherjee2, Ranjana Gangradey2, Alkesh Mavani1, Jyoti Agarwal2
  • Total Page Count: 7
  • Published Online: Jan 1, 2017
  • Page Number: 139 to 145

1LDRP Institute of Technology and Research, KSV UniversityGandhinagar

2Institute for Plasma Research, Gandhinagar, India

*Email: jatincho7531@gmail.com

Abstract

Hydroformed panels are widely used in fusion reactor components as a thermal radiation shield, for cryopumps and cryostats. In a cryopump, the pumping surface area is cooled down below 5K and is shielded from direct outer thermal radiation by using radiation shield panel cooled at 80K. Therefore, high cryogenic operational mass flows are required and thus pressure drop and heat transfer characteristics are important aspects of study. CFD analysis for radiation shield plate (2045 mm × 1800 mm × 3 mm) has been carried out when gaseous helium at 15 bar and 80K was inserted under heat flux of 365 W/m2. Further analyses were made for variable mass flow rate (i.e. 20 g/sec to 50 g/sec) to obtain optimum value of pressure drop with accurate thermal distribution on hydroformed shield plate.

Keywords

Cryopump, Radiation shield, Pressure drop, Heat transfer