Indian Journal of Clinical and Experimental Ophthalmology
  • Year: 2017
  • Volume: 3
  • Issue: 4

Evaluation of changes in IOP and anterior chamber parameters post laser irodotomy using pentacam system

  • Author:
  • Monika Kharbanda1, Ishwar Singh2,, Sachin Walia3, Harsimran Singh2
  • Total Page Count: 3
  • Page Number: 419 to 421

1Senior Resident, Dept. of Ophthalmology, Govt. Medical College, Patiala

2Assistant Professor, Dept. of Ophthalmology, Govt. Medical College, Patiala

3Professor & Head, Dept. of Ophthalmology, Govt. Medical College, Patiala

*Corresponding Author: Email: issaini2000@yahoo.in

Online published on 3 April, 2018.

Abstract

Aim of the study was to evaluate IOP changes and anterior chamber parameters (depth and volume), in primary angle closure (PAC) cases after laser peripheral irodotomy (LPI) using Pentacam system in OPD patients at Govt. Medical College, Patiala.

Total 12 eyes of 12 PAC patients were analysed in the study in the period of 3 months from March 2017 to May 2017. LPI was performed on the enrolled eyes, Pentacam system was used to calculate anterior chamber and IOP changes pre and post 14 days of LPI treatment.

There was statistically significant difference before LPI and after LPI for all measured variables. The mean ACD and ACV increased by p=0.04 and p = 0.001 respectively in 12 patients. The mean IOP decreased in all eyes with p=0.03 at month 3 and thereafter.

In conclusion, LPI produces significant anterior chamber depth & volume along with decrease in IOP making LPI effective in treatment of primary angle closure cases.

Keywords

IOP, Pentacam, LPI, Primary Angle closure