1Department of Civil Engineering, N.K. Orchid College of Engg, Solapur, India
2N.K. Orchid College of Engineering and Technology, Solapur, India
*Corresponding Email: rakeshnora123@gmail.com
Online published on 8 November, 2017.
The main purpose of this study is to regarding the economy, load carrying capacity of structural member. This study involving comparison between sectioned structural members for given requirement of superstructure part of an industrial building. Study reveals that, upto30% to 40% saving in cost is achieved by using tubular sections.
IS800–2007, IS806–1968, IS 875–1987 For tubular section, STAAD Pro 8Vi