Indian Journal of Public Health Research & Development

  • Year: 2019
  • Volume: 10
  • Issue: 11

A Clinical Study on Evaluation of Vertical Accuracy of Interocclusal Registration Materials in Centric Relation

  • Author:
  • Abhilash Mohapatra1, Jayshree Mohan2, Debarchita Sarangi3,, Paul Simon4
  • Total Page Count: 6
  • Page Number: 1341 to 1346

1Professor, Department of Prosthodontics and Crown & Bridge, Institute of Dental Sciences, Siksha ‘O’ Anusandhan (Deemed to be University), Bhubaneswar, Odisha, India

2Professor and HOD Department of Prosthodontics and Crown & Bridge, Vinayaka Mission's University, Salem, Tamil Nadu

3Assistant Professor, Department of Prosthodontics and Crown & Bridge, Institute of Dental Sciences, Siksha ‘O’ Anusandhan (Deemed to be University), Bhubaneswar, Odisha, India

4Professor, Vinayaka Mission College, Salem, Tamil Nadu, India

Abstract

The purpose of this study is to evaluate the ability to accurately record, maintain and reproduce vertical interocclusal relationship of four bite registration materials i.e. (Aluwax, zinc oxide eugenol, polyvinylsiloxane, bisacrylic resin bite registration materials).

It is necessary to evaluate recording materials for their accuracy to record, maintain and reproduce these maxillo-mandibular relationships as they are transferred from the mouth to the articulators.

Maxillary & mandibular cast were articulated in maximum intercuspation in split cast technique on the Whipmix articulator. This position was adopted as reference position for displacement measurement of the four materials. Two arbitrary points are selected on the right and left side of the cast to avoid operator tendency of repetition of the value. The measurements were calculated as the difference between the readings of the two points. The interocclusal records were placed and the measurements were taken. The difference in the two reading gave the vertical discrepancy with each material.

ANOVA and Tukey test were used. The result was statistically significant. Wax plus zinc oxide eugenol and wax plus aluwax showed significant difference statistically & clinically in recording the relationship.

The bisacrylic resin and polyvinylsiloxane bite registration materials can record the interocclusal relationship accurately. Wax plus zinc oxide eugenol paste and wax plus aluwax produced significant discrepancies in recording the relationship.

Keywords

Aluwax, bisacrylic resin, interocclusal records, Lucia Jig, polyvinylsiloxane