Indian Journal of Public Health Research & Development
  • Year: 2019
  • Volume: 10
  • Issue: 11

To Compare and Determine the Presence of Voids in Calcium Hydroxide, Epoxy Resin, and Tricalcium Silicate when Used as a Sealer in Single Cone Obturation Technique-An in Vitro Study

  • Author:
  • S.V. Satish1,, Krishnaprasad Shetty2, Jintu C. Thomas3, P. Rathnakar4, Jwala Chaitanya5, Alexander M. Luke6
  • Total Page Count: 5
  • Page Number: 2197 to 2201

1Prof and Head, Department of Conservative Dentistry and Endodontics, Navodaya Dental College, Raichur, Karnataka

2Lecturer, Department of Restorative Dentistry, College of Dentistry, Ajman University, Al-Jurf, Ajman, Post box No: 346, UAE

3Postgraduate Student, Department of Conservative Dentistry and Endodontics, Navodaya Dental College, Raichur, Karnataka

4Prof and Head, Department of Conservative and Endodontics, S. Nijalingappa Institute of Dental Sciences and Research, Sedam Road, Gulbarga, Karnataka

5Dental Surgeon, Jwalas Dental Centre, Hyderabad

6Assistant Professor, Department of Surgical Science, College of Dentistry, Ajman University, Al-Jurf, Ajman, Post Box no: 346, UAE

*Corresponding Author: Dr. S.V. Satish, Prof and Head, Department of Conservative Dentistry and Endodontics, Navodaya Dental College, Raichur, Karnataka, e-mail: jintucthomas002@gmail.com., 8606051599

Online published on 27 March, 2020.

Abstract

The purpose of this study was to evaluate and compare the area of voids in calcium hydroxide, epoxy-resin and tricalcium silicate-based sealers when employed with single cone obturation technique.

Fifteen extracted single-rooted mandibular premolar teeth were cleaned and shaped and divided into three groups according to the three different sealers used. Single cone obturation was done using gutta-percha and three sealers: Sealapex, AH Plus, and Bioroot RCS sealers, respectively. These teeth were decoronated at the cementoenamel junction and the roots were sectioned at apical, middle, and coronal third, and a stereomicroscope was used to assess the area of sealer voids and digital images were taken and was analyzed by image J software. The results were statistically analyzed using SPSS software and Kruskal-Wallis and Mann-Whitney tests.

All three groups showed voids in all the sections. Significant differences were found between these sealers regarding their section wise area of voids (P < 0.05). Similarly, there were significant differences in their overall area of voids (P < 0.05) with AH Plus showing significantly least area of voids followed by Sealapex.

Single cone obturation with AH Plus showed least mean area of voids, whereas Single cone obturation with BioRooot RCS had significantly the most mean area of voids.

Keywords

Sealapex, AH Plus, BioRoot RCS, voids, single cone obturation, stereomicroscope