Indian Journal of Public Health Research & Development
  • Year: 2019
  • Volume: 10
  • Issue: 11

Test Retest Reliability of Jittered Frequency Modulation Detection Test

  • Author:
  • A. Vidyarani1,, Arivudai Nambi Pitchaimuthu2, P.M. Akhilesh3, Jestin Joseph Chacko4
  • Total Page Count: 6
  • Page Number: 2493 to 2498

1Audiologist-Grade-II, Father Muller College of Speech and Hearing, Mangalore, Karnataka, India

2Associate Professor, Department of Audiology & Speech Language Pathology, Kasturba Medical College, Mangalore, Manipal Academy of Higher Education, Manipal

3Undergraduate Student, Father Muller College of Speech and Hearing, Mangalore, Karnataka, India

4Professor & Principal, Father Muller College of Speech and Hearing, Mangalore, Karnataka, India

*Corresponding Author: Ms. Vidyarani A., Audiologist-Grade II, Father Muller College of Speech and Hearing, Mangalore, Karnataka, India, e-mail: vidyarania@gmail.com

Online published on 27 March, 2020.

Abstract

Aim of the current is to develop a test to assess the perception of jitter in frequency modulation and also to assess its test-retest reliability. The motivation behind the development of such test is to detect subtle deficits such as hidden hearing disorder.

Observational study

Nine young adults participated in the current study. Initially, frequency modulation detection limen (FMDL) of the participants were assessed for 500 carrier frequency with 2Hz frequency modulation. Upon obtaining the FMDL, the jitter threshold was estimated as the lowest jitter at which the individual could differentiate the jittered frequency modulation from the sinusoidal frequency modulation. FMDL, jitter threshold at FMDL, and jitter threshold at 10Hz above the FMDL were measured twice. Both test and retest measurements were performed on the same day with the time gap of 20mins.

All participants could perceive frequency modulations and jitter in frequency modulation. Intra class correlation coefficient revealed good test-retest reliability for all measurements.

Since the developed test has good test-retest reliability, it has a potential implication in the assessment of subtle deficits such as hidden hearing disorder.

Keywords

Frequency modulation, FMDL, Temporal fine structure, TFS, Jittered frequency modulation, hidden hearing loss