To assess the quality of Digital Radiography (DR) with respect to various quality factors and parameters with conventional radiology(CR).
The study population included patients of all age groups apart from various out-patient departments for radiographs of varied body parts, thousand radiographs selected at random during the period of four months, had been evaluated for various quality parameters. Bed-side and inpatient radiographs ware excluded from the study.
The study showed as the radiographic quality of digital radiography imaging does not show significant difference over conventional X-rays; however the digital radiography unit scores over conventional radiography in decreased number of re-exposures and has the advantage of archiving and retrieval system.