Department of Dairy Chemistry, S.M.C College of Dairy Science, Anand Agricultural University, Anand-388 001, Gujrat, India
*Corresponding author's e-mail: kinpatel11@gmail.com
Online published on 30 January, 2019.
SNF/TS percent in cows'milk, collected from five dairy plants of Gujarat state were estimated using both volumetric and gravimetric method. Separate modified Richmond formulae for calculating SNF/TS have been proposed for each dairy plant. The equations worked out for individual dairy plant reflects region specificity in composition of milk. The correction factor ranged from 0.57 to 1.24 in one equation and 0.42 to 1.11 in the second to match with the results obtained by gravimetric method.
Correction factor, Gravimetric method, Lactometer method, Richmond formula, Solid-Not-Fat (SNF), Total Solids