1National Metallurgical Laboratory, Jamshedpur-831007.
2National Institute of Technolgy, Jamshedpur-831013.
*Corresponding Author Email: akbm@nmlindia.org
Aerospace high strength aluminium alloys are exposed to different environments and temperatures. In the present study, a high strength Al-Zn-Mg-Cu alloy and 3.5% NaCl solution have been selected. Potentiodynamic polarization test has been carried out using PARC 273 Potentiostat/Galvanostat (USA) at 298K, 313K, 328K and 343K. Saturated calomel electrode (SCE) and graphite rod have been selected as a reference and auxiliary electrode respectively. It has been observed that aggressiveness of the solution at above temperatures increases, resulting rapid dissolution and higher corrosion rate with the rise of temperature.
Temperature effect, Corrosive medium, Aluminium alloy