Research Journal of Pharmacy and Technology

SCOPUS
  • Year: 2018
  • Volume: 11
  • Issue: 12

Comparison of Shear Bond Strength of Different Light Cure Orthodontic Adhesives-An In vitro Study

1Postgraduate Student, Department of Orthodontic, Saveetha Dental College, Chennai, India

2Reader, Department of Orthodontics, Saveetha Dental College, Chennai, India

*Corresponding Author E-mail:

Online published on 18 May, 2019.

Abstract

The aim of the study was to evaluate and compare the shear bond strength of the brackets bonded with two different orthodontic light cure adhesives.

Ten extracted human premolars were divided into 2 groups. Premolar brackets were bonded to the tooth specimens in each group with their respective adhesive according to the manufacturer's instructions. Group1-bonded with Transbond XT [3M UNITEK] and Group2-tooth specimen bonded with Grengloo[Ormco] and then examined for shear bond strength. The teeth were placed in INSTRON universal testing machine at crosshead speed of 0.5 mm/minute, and the shear force to remove the brackets was recorded.

The independent test revealed that there was no significant difference between the shear bond strength of the two groups. The mean shear bond strengths of two adhesive systems showed no significant differences.

The mean shear bond strengths of two adhesive systems showed no significant differences

Keywords

Light-cure adhesive[Transbond XT, Grengloo], Shear bond strength, Orthodontic Brackets, Light cure units, Instron machine