D.S.T.S Mandal's College of Pharmacy, Solapur - 413004, Maharashtra, India
*Corresponding Author E-mail: avibirajdar1998@gmail.com
Online published on 25 August, 2021.
A new, simple, sensitive, precise, reproducible UV visible spectrophotometric method was developed for the determination of Darunavir in Tablet dosage form with 0.1N HCl.
The method is based on the formation of a colorless complex. The UV spectrum of Darunavir in 0.1N HCl showed maximum wavelength at 298nm. Beer's law is valid in the concentration range of 10–60μg/ml. this method was validated for linearity, accuracy, precision, assay, ruggedness and robustness.
The method has demonstrated excellent linearity over the range of 10–60μg/ml with the regression equation y=0.0113x+0.0098, and regression coefficient i.e. r2=0.9992 moreover, the method was found to be highly sensitive with LOD (1.85μg/ml) and LOQ (5.62μg/ml).
Based on the results the proposed method can be successfully applied for the assay of Darunavir in various tablet dosage forms.
Darunavir, UV visible spectrophotometer, 0.1N HCl, Method development and validation