Research Journal of Pharmacy and Technology

SCOPUS
  • Year: 2024
  • Volume: 17
  • Issue: 11

ICH Guideline in Practice for Quantification of Ruxolitinib by applying Validated RP-HPLC Method on Commercial Tablet Formulation

  • Author:
  • Minal Harde1,*, Sameer Lakade2, Ujwala Wasnik3, Shejal Wakade1, Komal Doifode1, Kamlesh Palandurkar4, Shrikant Joshi5, Laxman Ingole1
  • Total Page Count: 5
  • Page Number: 5242 to 5246

1Modern College of Pharmacy, Sector No. 21, Yamuna Nagar, Nigdi, Pune, Maharashtra, India

2RMD Institute of Pharmaceutical Education and Research, Pune, Maharashtra, India

3Taywade College of Pharmacy, Koradi, Nagpur, Maharashtra, India

4Department of Biochemistry, Institute of Medical Sciences, Banaras Hindu University, Varanasi, India

5Department of Pharmacology, Maliba Pharmacy College, Maliba-Mahuva Road, Tarsadi, Dist- Surat, Gujarat, India

Abstract

The current investigation explains the validation of High Pressure Liquid Chromatography (HPLC) technique for quantification of Ruxolitinib in active ingredient and marketed tablet dosage form. For assessment of Ruxolitinib, a specific column chromatographic method has been developed using UV detection.

The chromatographic elution was executed on ODS Phenomenex analytical column (250mm × 4.6mm, 5μm particle size). The solvent ratio utilized was methanol: water (pH 3.5 adjusted with OPA) (70:30 V/V). A constant ratio of eluting phase flow rate 1.0ml/min was used to detect RTB at 236nm.

The developed method was justified using various variables such as accuracy, limit of detection, precision, specificity, robustness, limit of quantification. The retention time for Ruxolitinib was obtained at 8.59 min. The designed method was detected linear within 20 to 120μg/ml range. Correlation coefficient (r2) of the regression equation was found to be 0.9999. Detection and quantitation limit achieved was 0.1496 and 0.4483 respectively. The accuracy of the method was determined using recovery study. The % recovery obtained was in the range of 98.68 – 99.80%. All system suitability factors like tailing factor, retention factor, number of theoretical plates were obtained within acceptance range. The obtained result demonstrates that the presented method is reliable, precise, and economical.

The specified method was effectively authenticated as per guidelines of ICH in practice and can be claimed successful for the determination of Ruxolitinib in commercial formulation.

Keywords

RP–HPLC, Quantification, Ruxolitinib, Validation, ICH guidelines