1Department of Chemistry, Krishna University, Machilipatnam, Andhra Pradesh, India
2Department of Chemistry, S.V. University, Tirupathi, Andhra Pradesh, India
3Department of Chemistry, S.K. University, Anantapur, Andhra Pradesh, India
4Department of Pharmaceutics, GRY Institute of Pharmacy, Madhya Pradesh, India
*Corresponding Author E-mail: tentu6581@rediffmail.com
Online published on 29 August, 2014.
A simple, sensitive and inexpensive method was developed using matrix solid-phase dispersion (MSPD), together with high performance liquid chromatographic method for determination of Tetracycline residues and its metabolite 4-Epitetracycline in cow milk. The evaluated parameters included the type and amount of sorbent (silica gel, C18 and alumina) and the nature of eluent (20% trichloro acetic acid, 0.01M citric acid, 0.01M disodium hydrogen phosphate, 0.01M EDTA and Methanol). The best results were obtained using 10 mL of milk sample, 1.0 g of C18 as sorbent and 20mL of 20% trichloroacetic acid, 0.01M citric acid, 0.01M disodium hydrogen phosphate, 0.01M EDTA and Methanol (1:2:2:2:3, (v/v)).The method was validated using in milk samples spiked with Tetracycline residues and its metabolite 4-Epitetracycline at different concentration levels (0.05 and 0.5 μg/mL). Average recoveries (using each concentration six replicates) ranged 87–96%, with relative standard deviations less than 2%, calibration solutions concentration in the range 0.05–5.0 μg/mL and limit of detection (LOD) and limit of quantification (LOQ) were 0.02 μg/mL and 0.05 μg/mL respectively.
Matrix solid-phase dispersion, antibiotic residues, LOD and LOQ