Water and Energy Abstracts
Open Access
  • Year: 2004
  • Volume: 14
  • Issue: 1

120. Concentration and Particle Size Distribution in the Flow of Multi-Sized Particulate Slurry Through Rectangular Duct

  • Author:
  • D.R. Kaushal, V. Seshadri, S.N. Singh
  • Total Page Count: 1
  • Page Number: 44 to 44

(JHH, Journal of Hydrology and Hydromechanics, No. 2, Vol. 51, 2003, pp. 114–121).

Abstract

Concentration and particle size distribution has been experimentally measured in a 2D rectangular duct under near iso-kinetic conditions for multi-sized particulate slurry. Measurements have been made at different flow velocities for various efflux concentrations in the range of 10 to 50% by weight. It is observed that the concentration profile is highly skewed towards the bottom of the duct, which reduces with increase in efflux concentration and velocity. Similar phenomenon is observed in the distribution of individual particle size fractions with the effect being more pronounced for the coarser particles.

Keywords

Concentration profile, Particle size distribution, Rectangular duct, Multi-sized particulate slurry, Weighted mean diameter